Controllers - AQ Matic and Control Valves
Process controllers read signals from sensors and adjust outputs to hold temperature, pressure, flow or level at set point. They range from simple panel meters to advanced PID controllers.
Controller Products
- PID controllers – precise closed-loop control
- Process meters – display and alarm process signals
- Panel meters and displays – local indication
Choosing a Controller
Match inputs (thermocouple, RTD, mA, voltage) and outputs (relay, SSR, analog) to your process. Consider alarms, ramp/soak programming and communications. Panel size (1/16, 1/8, 1/4 DIN) affects layout.
Centro offers controllers and displays for process and temperature control.
Shop by type: Panel Meters and Displays | PID
Related categories: Instrumentation, Measurement and Control | Recorders | Pressure Control | Instrument/Compression Fittings | Flow Control
Help us help you.
No matches exist in our product database, but we can still help get you what you need. Fill out the form to the right and we’ll get back to you within 48 hours.
- Process controllers are devices that receive a measurement input from a sensor or transmitter, compare it to a setpoint, and generate an output signal to drive a final control element (valve, heater, pump, etc.). The main types include PID controllers (the industry standard for continuous process control — they use proportional, integral, and derivative algorithms to maintain the process variable at setpoint), process meters (display and monitor process variables with alarm outputs but may not have full PID control capability), and panel meters (display electrical signals — current, voltage, frequency — on a panel for operator visibility). Controllers are available as standalone DIN-rail or panel-mount units, or as software function blocks within a PLC or DCS.
- PID stands for Proportional-Integral-Derivative — three mathematical terms that together calculate the controller's output to minimize the error between the measured process variable and the desired setpoint. The Proportional term responds to the current error (how far the measurement is from setpoint), the Integral term responds to accumulated past error (correcting for persistent offset), and the Derivative term responds to the rate of change of error (dampening overshoot). PID control is the standard because it handles the vast majority of industrial process loops — temperature, pressure, flow, level — reliably and predictably. A well-tuned PID controller brings the process to setpoint quickly, with minimal overshoot, and holds it there despite disturbances. Most modern process controllers include auto-tuning features that automatically calculate optimal PID parameters for the specific loop.
- Start with the process requirements: what variable are you controlling (temperature, pressure, flow, level), what sensor type provides the input (thermocouple, RTD, 4–20 mA transmitter), and what type of output is needed to drive the final control element (4–20 mA analog, relay, SSR driver, pulse). Then consider the control mode — simple on/off control (sufficient for non-critical applications like tank heaters with wide deadbands), PID control (required for tight setpoint control), or more advanced control like cascade, ratio, or ramp/soak profiles (for complex processes like heat treatment or batch reactions). Physical format matters too — 1/16 DIN, 1/8 DIN, and 1/4 DIN sizes refer to the panel cutout dimensions and correspond to different display sizes and feature levels. Finally, verify communication options (RS-485, Modbus, Ethernet) if the controller needs to interface with a PLC, SCADA, or data logging system.
- A process meter measures, displays, and monitors a process variable — it accepts a sensor or transmitter input, shows the current value on a digital display, and can trigger alarm outputs when the value exceeds high or low thresholds. However, a process meter does not generate a modulating control output to drive a valve or heater — it is primarily an indicator and alarm device. A PID controller does everything a process meter does and adds closed-loop control — it continuously calculates and outputs a control signal (4–20 mA, relay, or SSR) to adjust the process and maintain the variable at setpoint. If your application only requires monitoring and alarming (e.g., displaying tank level with a high-level alarm), a process meter is sufficient and more cost-effective. If the application requires active control (e.g., maintaining furnace temperature at 350°F by modulating a gas valve), a PID controller is required.
- A ramp/soak profile is a programmed temperature (or other variable) trajectory that the controller follows over time — ramping the setpoint up or down at a defined rate, then holding (soaking) at a target value for a defined duration, then ramping to the next step. This is essential for processes where the rate of change matters as much as the final value — such as heat treatment (metallurgical tempering, annealing, stress relieving), ceramics firing, curing composites, pharmaceutical drying, and environmental test chambers. A controller with ramp/soak capability can store multi-step programs (e.g., ramp to 500°F at 5°F/minute, hold for 2 hours, ramp to 800°F at 3°F/minute, hold for 1 hour, cool to 200°F at 2°F/minute) and execute them automatically. Controllers vary in the number of steps and programs they can store — verify that the controller supports enough steps for your most complex process profile.