Categories from Danfoss (4)

Electric Motor Controls
Electric Motor Controls

Electronic motor control is vital for modern pump systems, enhancing efficiency and reliability by managing motor speed, torque, and direction. Utilizing variable frequency drives (VFDs) and programmable logic controllers (PLCs) helps optimize energy consumption, reduce mechanical wear, and improve system protection across various applications, including industrial processes, water treatment, and HVAC systems.


How does a variable frequency drive (VFD) work in pump control?

A variable frequency drive (VFD) controls a pump by adjusting the motor's speed and torque to match what's needed. It takes the incoming AC power, converts it to DC, and then back to AC at the right frequency and voltage. By changing the frequency, the VFD can adjust the motor speed, and by controlling the voltage, it keeps the torque just right. This precise control helps improve energy efficiency, reduces wear and tear on the system, and keeps everything running smoothly.


How does programmable logic controllers (PLCs) play in pump motor control?

Programmable logic controllers (PLCs) are key to pump motor control because they automate and monitor the system. They can start and stop the pump, adjust the motor speed, and respond to different inputs and conditions. PLCs also detect faults, schedule operations, and optimize processes to ensure everything runs smoothly and efficiently. Their ability to handle complex control tasks makes them essential for keeping pump systems reliable and efficient.


Do you have questions regarding electronic motor control products for pumps?

Contact us to speak with a product expert to help you from product selection to answering questions about installation.

Adjustable Frequency Drives
Adjustable Frequency Drives

Adjustable Frequency Drives (AFDs), also known as Variable Frequency Drives (VFDs), optimize motor performance by precisely controlling speed and torque, improving energy efficiency and extending equipment life. Commonly used in HVAC, manufacturing, and pumping systems, AFDs enhance process control, reduce power consumption, and minimize mechanical stress on motors. With features like soft starting, programmable acceleration, and advanced diagnostics, these drives support smarter, more efficient industrial operations.

Softstarts
Softstarts

Soft starters provide controlled acceleration and deceleration of electric motors by gradually ramping up voltage, reducing mechanical stress, inrush current, and wear on equipment in industrial pumping, conveying, and HVAC systems. Ideal for fixed-speed applications, they enhance system reliability, extend motor life, and prevent issues like water hammer or belt slippage. With features such as torque control, bypass contactors, and built-in diagnostics, soft starters offer a compact, cost-effective solution for smooth motor starting in demanding industrial environments.

Motor Control Parts
Motor Control Parts

Motor control parts are used to manage and regulate the operation of electric motors in various industrial and commercial applications. They include devices such as contactors, relays, motor starters, and variable frequency drives (VFDs), which control motor speed, direction, and protection. These parts are for smooth motor operation, energy efficiency, and safety in machinery, HVAC systems, and automation equipment. Browse our selection below or contact us to speak with a product expert.

Filter
Filter
2,005 items
content loaded
Danfoss - 132H2237
MPN:MCD60160CT7S2X00CV2
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$2,550.49$2,810.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2239
MPN:MCD60215CT7S2X00CV2
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$3,291.13$3,626.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2240
MPN:MCD60275CT7S2X00CV2
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$3,538.01$3,898.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2241
MPN:MCD60343CT7S2X00CV2
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$3,785.80$4,171.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2243
MPN:MCD60448CT7S2X00CV2
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$4,087.14$4,503.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2244
MPN:MCD60160CT7S2X00CV1
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$2,550.49$2,810.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2245
MPN:MCD60215CT7S2X00CV1
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$3,291.13$3,626.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2246
MPN:MCD60275CT7S2X00CV1
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$3,538.01$3,898.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2247
MPN:MCD60343CT7S2X00CV1
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$3,785.80$4,171.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2248
MPN:MCD60448CT7S2X00CV1
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$4,087.14$4,503.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2250
MPN:MCD60065BTXSES12CVE
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$6,581.36$7,251.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2252
MPN:MCD60180BTXSES12CVE
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$10,968.93$12,085.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2253
MPN:MCD60240BTXSES12CVE
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$12,067.18$13,295.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2255
MPN:MCD60065BTXSES3RCVE
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$7,460.87$8,220.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2257
MPN:MCD60180BTXSES3RCVE
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$12,067.18$13,295.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2258
MPN:MCD60240BTXSES3RCVE
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$14,260.06$15,711.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2261
MPN:MCD60065BTXSEH12CVE
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$7,020.66$7,735.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2263
MPN:MCD60180BTXSEH12CVE
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$11,518.96$12,691.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2264
MPN:MCD60240BTXSEH12CVE
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$13,163.62$14,503.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2266
MPN:MCD60065BTXSEH3RCVE
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$7,897.45$8,701.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2268
MPN:MCD60180BTXSEH3RCVE
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$12,615.40$13,899.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2269
MPN:MCD60240BTXSEH3RCVE
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$14,808.28$16,315.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H8440
MPN:MCD60124BTXSES12CVE
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$9,325.18$10,274.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H8442
MPN:MCD60361BTXSES12CVE
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$15,357.40$16,920.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2237
MPN:MCD60160CT7S2X00CV2
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$2,550.49$2,810.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2239
MPN:MCD60215CT7S2X00CV2
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$3,291.13$3,626.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2240
MPN:MCD60275CT7S2X00CV2
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$3,538.01$3,898.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2241
MPN:MCD60343CT7S2X00CV2
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$3,785.80$4,171.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2243
MPN:MCD60448CT7S2X00CV2
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$4,087.14$4,503.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2244
MPN:MCD60160CT7S2X00CV1
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$2,550.49$2,810.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2245
MPN:MCD60215CT7S2X00CV1
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$3,291.13$3,626.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2246
MPN:MCD60275CT7S2X00CV1
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$3,538.01$3,898.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2247
MPN:MCD60343CT7S2X00CV1
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$3,785.80$4,171.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2248
MPN:MCD60448CT7S2X00CV1
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$4,087.14$4,503.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2250
MPN:MCD60065BTXSES12CVE
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$6,581.36$7,251.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2252
MPN:MCD60180BTXSES12CVE
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$10,968.93$12,085.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2253
MPN:MCD60240BTXSES12CVE
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$12,067.18$13,295.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2255
MPN:MCD60065BTXSES3RCVE
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$7,460.87$8,220.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2257
MPN:MCD60180BTXSES3RCVE
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$12,067.18$13,295.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2258
MPN:MCD60240BTXSES3RCVE
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$14,260.06$15,711.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2261
MPN:MCD60065BTXSEH12CVE
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$7,020.66$7,735.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2263
MPN:MCD60180BTXSEH12CVE
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$11,518.96$12,691.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2264
MPN:MCD60240BTXSEH12CVE
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$13,163.62$14,503.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2266
MPN:MCD60065BTXSEH3RCVE
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$7,897.45$8,701.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2268
MPN:MCD60180BTXSEH3RCVE
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$12,615.40$13,899.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H2269
MPN:MCD60240BTXSEH3RCVE
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$14,808.28$16,315.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H8440
MPN:MCD60124BTXSES12CVE
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$9,325.18$10,274.00

You save 9%
Available for Purchase

Subject to factory lead times

Danfoss - 132H8442
MPN:MCD60361BTXSES12CVE
VLT® Soft Starter MCD 600 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profile for the application. Emergency mode and Pump clean function are standard features. The optional remote control panel adds more functionality, such as the Start/Stop buttons, and quick jump buttons to menu options. VLT® Soft Starter MCD 600 is available in three enclosure sizes: S1, S2 and S3 S1: IP20 with built-in bypass contactor (20–129 A) S2: IP00 either with built-in bypass or non-bypass (144 –579 A). S3: IP00 with built-in bypass, non-bypass or external bypass (590–1250 A) To achieve protection rating IP20 on connections, order the Finger Guard Kit as an accessory.

$15,357.40$16,920.00

You save 9%
Available for Purchase

Subject to factory lead times