Transducers - Numatics
Transducers are devices that convert energy from one form to another. Pressure transducers are devices that convert pressure into an electrical signal. Signal transducers convert an electrical signal into another form of energy. Centro carries a complete selection of transducers available to purchase online. Centro's transducers are available in different models and sizes to suit your application needs. Whatever your transducer needs, Centro has the products to get the job done. Please browse our website today to learn more about our complete selection of transducers.
$1,037.51$1,286.52
Subject to factory lead times
Subject to factory lead times
Subject to factory lead times
$1,065.06$1,320.68
Subject to factory lead times
Subject to factory lead times
Subject to factory lead times
$1,078.34$1,337.15
Subject to factory lead times
$1,075.51$1,333.63
Subject to factory lead times
$747.03$926.32
Subject to factory lead times
Subject to factory lead times
$747.03$926.32
Subject to factory lead times
$723.00$896.52
Subject to factory lead times
$1,037.51$1,286.52
Subject to factory lead times
Subject to factory lead times
Subject to factory lead times
$1,065.06$1,320.68
Subject to factory lead times
Subject to factory lead times
Subject to factory lead times
$1,078.34$1,337.15
Subject to factory lead times
$1,075.51$1,333.63
Subject to factory lead times
$747.03$926.32
Subject to factory lead times
Subject to factory lead times
$747.03$926.32
Subject to factory lead times
$723.00$896.52
Subject to factory lead times
- An I/P (current-to-pressure) transducer converts an electrical current signal — typically 4–20 mA from a PLC, DCS, or controller — into a proportional pneumatic pressure output, usually 3–15 psi. This conversion is essential because most modern control systems generate electrical output signals, but pneumatic valve actuators and positioners require a pneumatic input to operate. The I/P transducer bridges this gap, allowing an electronic control system to drive a pneumatic actuator. Inside the transducer, the electrical current energizes a coil that acts on a nozzle-flapper or force-balance mechanism, modulating air pressure in direct proportion to the input current. A 4 mA input produces the minimum output pressure (typically 3 psi), and a 20 mA input produces the maximum output pressure (typically 15 psi), with a linear relationship in between. I/P transducers are mounted close to the actuator and require a clean, regulated instrument air supply to function properly.
- Both devices convert an electrical signal into pneumatic output to control a valve actuator, but they differ in functionality and where they fit in the control loop. An I/P transducer is a standalone signal converter — it takes a 4–20 mA input and produces a proportional 3–15 psi output, but it has no feedback from the valve position. It simply converts the signal and sends it downstream. An electropneumatic (E/P) positioner receives the same 4–20 mA input but also has a mechanical or electronic feedback linkage connected to the valve stem or actuator shaft. The positioner continuously compares the control signal to the valve's actual position and adjusts the pneumatic output to eliminate any error — providing closed-loop control at the valve. If your actuator already has a pneumatic positioner, you may need an I/P transducer upstream to convert the electronic signal to pneumatic. If you use a digital electropneumatic positioner, it accepts the 4–20 mA signal directly and no separate I/P transducer is needed.
- Selecting the right I/P transducer involves matching the input signal range, output pressure range, air consumption, and environmental requirements to your application. Verify the input signal — most transducers accept the standard 4–20 mA range, but some applications may use split-range signals (4–12 mA or 12–20 mA) that require a transducer with adjustable zero and span. Confirm the output pressure range matches the downstream device — 3–15 psi is standard for positioners and pneumatic controllers, but some actuators or volume boosters may require higher output ranges (up to 30 psi or 60 psi). Consider air consumption — lower steady-state air consumption reduces the load on the instrument air supply, which matters in installations with many transducers. For outdoor or corrosive environments, specify a weatherproof or corrosion-resistant enclosure. For hazardous classified areas, the transducer must carry the appropriate explosion-proof or intrinsically safe certification. Finally, verify the mounting configuration — most I/P transducers use a standard 1/4-inch NPT connection for the air supply and output.
- A P/I (pressure-to-current) transducer does the opposite of an I/P transducer — it converts a pneumatic pressure signal into a proportional electrical current signal, typically 4–20 mA. P/I transducers are used when a pneumatic instrument or device generates a pressure output that needs to be read by an electronic control system. Common applications include converting the output of a pneumatic controller, a pneumatic level transmitter, or a pneumatic temperature transmitter into a 4–20 mA signal that can be wired to a PLC or DCS input. They are also used to monitor actuator supply pressure or positioner output pressure by converting the air pressure into an electrical signal for trending and alarming in the control system. P/I transducers are less common than I/P transducers in new installations because most modern instruments are electronic, but they remain essential for integrating legacy pneumatic instruments into modern digital control systems without replacing the field devices.
- Instrument air quality is critical because transducers and positioners contain precision internal components — small orifices, nozzles, diaphragms, and seating surfaces — that are extremely sensitive to contamination. Moisture in the air supply causes corrosion of internal metal parts, swelling and degradation of elastomer seals, and ice formation in cold environments that can completely block air passages. Oil contamination coats diaphragms and nozzles, causing them to stick and respond sluggishly or inaccurately. Particulates lodge in the tiny orifices and nozzle gaps, causing erratic pressure output and loss of calibration. The instrument air supply should meet ISA-7.0.01 quality standards — a dew point at least 18°F below the minimum ambient temperature, oil content below 1 ppm, and particle size below 40 microns (3 microns for more sensitive devices). A properly maintained filter-regulator at the point of use, combined with a well-functioning plant air dryer, prevents the vast majority of transducer and positioner failures related to air quality.