Overview:

CD01-PA VER 10 Modi R414012058. Compressed-air system component for OEM machinery and factory automation. Used by machine builders integrating pneumatic subsystems into automated production equipment. Available from us as an authorized Aventics distributor with manufacturer warranty.

Features:

  • Aventics Series CD01 ISO 15407-1 valve system / directional control valve
  • Variants: CD01-PA (pneumatic / individual valve), CD01-PI (manifold valve system, internally piloted)
  • 5/2, 5/3 (closed/exhaust/supplied center), and 2x3/2 spool functions
  • Spool valve, positive overlapping, 26 mm pilot valve width
  • ISO 15407-1 base-plate connection (sub-base mounting)
  • Vacuum-capable: -0.9 to 16 bar working pressure
  • Compressed air connection: G 1/8, G 1/4, or push-in tube fittings (3, 4, 6, 8, 10 mm)
  • High flow: 1010 l/min nominal Qn (system) up to 1.01 Cv per valve
  • 24 V DC operation, IP65 protection with connection
  • Multipole D-Sub or fieldbus electrical connection on manifold (CD01-PI)
  • Manual override standard on each pilot
  • ISO 15407-1 standardized footprint enables direct interchange with other compliant manifolds
  • Suitable for general machine automation, packaging, and material-handling applications

Specifications:

  • Series: CD01 ISO 15407-1 valve system (Aventics)
  • Variants:
  • - CD01-PA: Individual valve, pneumatic
  • - CD01-PI: Manifold valve system, internally piloted (26 mm)
  • Standard: ISO 15407-1 (sub-base footprint)
  • Function: 5/2 single solenoid, 5/2 double solenoid, 5/3 closed/exhaust/supplied center, 2x3/2
  • Valve type: Spool, positive overlapping
  • Pilot valve width: 26 mm
  • Working pressure: -0.9 to 16 bar (vacuum capable; configuration-dependent)
  • Control pressure: Configuration-dependent — for externally piloted valves min. control pressure depends on working pressure (refer to PB curve)
  • Ambient temperature: -15 to +50 °C
  • Medium temperature: -15 to +50 °C
  • Medium: Compressed air; max particle size 5 µm; oil content 0–5 mg/m³
  • Pressure dew point: ≥15 °C below ambient/medium temperature, ≤3 °C
  • Nominal flow Qn (system): 1010 l/min at 6 bar, Δp = 1 bar
  • Nominal flow per valve: typically 0.65–1.01 Cv
  • Compressed air connection: ISO 15407-1 base plate; G 1/8 / G 1/4 ports or push-in tube (3, 4, 6, 8, 10 mm)
  • Pilot type: Internal or external pilot
  • Operating voltage: 24 V DC, tolerance -10% / +10%; AC 50/60 Hz variants available
  • Protection class: IP65 with connection
  • Manifold electrical connection (CD01-PI): Multipole D-Sub or fieldbus (PROFIBUS DP, CANopen, DeviceNet, PROFINET IO, EtherCAT, EtherNet/IP)
  • Manual override: Standard on each pilot (locking and non-locking variants)
  • Reverse polarity protection: Yes
  • Materials: Aluminum body, NBR/PUR seals
  • Notes: Versions with voltage <50 V DC do not have protective ground
  • Application: General machine automation, packaging machinery, material handling, manifold-mounted valve systems
Quote

"Our mission is to be regarded by our customers and our community as the best supplier of automation and control product solutions to industry."

Michael R Gallagher

Centro President

QTY:

CD01-PA VER 10 Modi R414012058
Image may not be the actual product. Please refer to the full technical specs and MPN for exact details.
CD01-PA VER 10 Modi R414012058

MPN: R414012058

Part # R414012058

Requires Quote