Categories from Watson McDaniel (2)

Steam Traps
Steam Traps

Steam traps are essential for any business that uses steam to power its machinery. They are responsible for removing condensate from the piping, which can build up and cause damage if left unchecked. Steam traps come in a variety of different designs, each with its advantages and disadvantages. The most common types are thermostatic, inverted buckets, and mechanical traps. Thermostatic traps are the most common type of steam trap, and they use a sensing element to open and close the valve in response to changes in temperature. Inverted bucket traps use a float to control the valve and are well-suited for applications where large volumes of condensate need to be removed. Mechanical traps use a diaphragm or piston to open and close the valve and are often used in high-pressure applications. No matter what type of steam trap you need, Centro has a complete selection available online.

Regulators
Regulators

Regulators are devices that control the pressure of gases and liquids. Centro carries a complete selection of regulators available to purchase online, including compress air regulators, FRL compressed air regulators, and air regulators. Our compress air regulators are designed to maintain a constant output pressure, even as the input pressure changes. Our FRL compressed air regulators are ideal for applications where the inlet pressure is unstable or unknown. And our air regulators can be used to adjust the flow rate of gases. We have the perfect solution for your commercial or industrial application. Please browse our website today to find the suitable regulator for your needs.

Filter
Filter
612 items
content loaded
The Watson McDaniel SIBH-13-N-200 is a stainless steel inverted bucket steam trap with a 3/4" NPT connection, stainless steel internals, and a max working pressure of 200 PSI. The IB inverted bucket steam traps were specifically designed for removing condensate from steam mains & steam supply lines. Inverted bucket traps can also be used on unit heaters, laundry equipment, and other less critical process applications where slow start-up due to poor air handling characteristics can be tolerated. These traps can handle superheated steam when a check valve is used on the inlet side, which prevents the trap from losing prime.

$493.38

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel SIBH-13-N-250 is a stainless steel inverted bucket steam trap with a 3/4" NPT connection, stainless steel internals, and a max working pressure of 250 PSI. The IB inverted bucket steam traps were specifically designed for removing condensate from steam mains & steam supply lines. Inverted bucket traps can also be used on unit heaters, laundry equipment, and other less critical process applications where slow start-up due to poor air handling characteristics can be tolerated. These traps can handle superheated steam when a check valve is used on the inlet side, which prevents the trap from losing prime.

$493.38

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel SIBH-13-N-30 is a stainless steel inverted bucket steam trap with a 3/4" NPT connection, stainless steel internals, and a max working pressure of 30 PSI. The IB inverted bucket steam traps were specifically designed for removing condensate from steam mains & steam supply lines. Inverted bucket traps can also be used on unit heaters, laundry equipment, and other less critical process applications where slow start-up due to poor air handling characteristics can be tolerated. These traps can handle superheated steam when a check valve is used on the inlet side, which prevents the trap from losing prime.

$493.38

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel SIBH-13-N-450 is a stainless steel inverted bucket steam trap with a 3/4" NPT connection, stainless steel internals, and a max working pressure of 450 PSI. The IB inverted bucket steam traps were specifically designed for removing condensate from steam mains & steam supply lines. Inverted bucket traps can also be used on unit heaters, laundry equipment, and other less critical process applications where slow start-up due to poor air handling characteristics can be tolerated. These traps can handle superheated steam when a check valve is used on the inlet side, which prevents the trap from losing prime.

$493.38

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel SIBH-13-N-70 is a stainless steel inverted bucket steam trap with a 3/4" NPT connection, stainless steel internals, and a max working pressure of 70 PSI. The IB inverted bucket steam traps were specifically designed for removing condensate from steam mains & steam supply lines. Inverted bucket traps can also be used on unit heaters, laundry equipment, and other less critical process applications where slow start-up due to poor air handling characteristics can be tolerated. These traps can handle superheated steam when a check valve is used on the inlet side, which prevents the trap from losing prime.

$493.38

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel SIBH-13-SW-125 is a stainless steel inverted bucket steam trap with a 3/4" socket weld connection, stainless steel internals, and a max working pressure of 125 PSI. The IB inverted bucket steam traps were specifically designed for removing condensate from steam mains & steam supply lines. Inverted bucket traps can also be used on unit heaters, laundry equipment, and other less critical process applications where slow start-up due to poor air handling characteristics can be tolerated. These traps can handle superheated steam when a check valve is used on the inlet side, which prevents the trap from losing prime.

$493.38

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel SIBH-13-SW-15 is a stainless steel inverted bucket steam trap with a 3/4" socket weld connection, stainless steel internals, and a max working pressure of 15 PSI. The IB inverted bucket steam traps were specifically designed for removing condensate from steam mains & steam supply lines. Inverted bucket traps can also be used on unit heaters, laundry equipment, and other less critical process applications where slow start-up due to poor air handling characteristics can be tolerated. These traps can handle superheated steam when a check valve is used on the inlet side, which prevents the trap from losing prime.

$493.38

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel SIBH-13-SW-200 is a stainless steel inverted bucket steam trap with a 3/4" socket weld connection, stainless steel internals, and a max working pressure of 200 PSI. The IB inverted bucket steam traps were specifically designed for removing condensate from steam mains & steam supply lines. Inverted bucket traps can also be used on unit heaters, laundry equipment, and other less critical process applications where slow start-up due to poor air handling characteristics can be tolerated. These traps can handle superheated steam when a check valve is used on the inlet side, which prevents the trap from losing prime.

$493.38

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel SIBH-13-SW-250 is a stainless steel inverted bucket steam trap with a 3/4" socket weld connection, stainless steel internals, and a max working pressure of 250 PSI. The IB inverted bucket steam traps were specifically designed for removing condensate from steam mains & steam supply lines. Inverted bucket traps can also be used on unit heaters, laundry equipment, and other less critical process applications where slow start-up due to poor air handling characteristics can be tolerated. These traps can handle superheated steam when a check valve is used on the inlet side, which prevents the trap from losing prime.

$493.38

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel SIBH-13-SW-30 is a stainless steel inverted bucket steam trap with a 3/4" socket weld connection, stainless steel internals, and a max working pressure of 30 PSI. The IB inverted bucket steam traps were specifically designed for removing condensate from steam mains & steam supply lines. Inverted bucket traps can also be used on unit heaters, laundry equipment, and other less critical process applications where slow start-up due to poor air handling characteristics can be tolerated. These traps can handle superheated steam when a check valve is used on the inlet side, which prevents the trap from losing prime.

$493.38

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel SIBH-13-SW-450 is a stainless steel inverted bucket steam trap with a 3/4" socket weld connection, stainless steel internals, and a max working pressure of 450 PSI. The IB inverted bucket steam traps were specifically designed for removing condensate from steam mains & steam supply lines. Inverted bucket traps can also be used on unit heaters, laundry equipment, and other less critical process applications where slow start-up due to poor air handling characteristics can be tolerated. These traps can handle superheated steam when a check valve is used on the inlet side, which prevents the trap from losing prime.

$493.38

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel SIBH-13-SW-70 is a stainless steel inverted bucket steam trap with a 3/4" socket weld connection, stainless steel internals, and a max working pressure of 70 PSI. The IB inverted bucket steam traps were specifically designed for removing condensate from steam mains & steam supply lines. Inverted bucket traps can also be used on unit heaters, laundry equipment, and other less critical process applications where slow start-up due to poor air handling characteristics can be tolerated. These traps can handle superheated steam when a check valve is used on the inlet side, which prevents the trap from losing prime.

$493.38

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel ST3001S-12-SW is a stainless steel thermostatic steam trap with a 1/2" socket weld connection, stainless steel internals, and a max working pressure of 650 PSI. This steam trap has a strainer. The WT3000 is a medium capacity thermostatic steam trap which was specifically designed for removing condensate and air from process applications. The body is made from stainless steel and is fully repairable while the product remains in-line.
Requires Quote
Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel ST3001S-13-SW is a stainless steel thermostatic steam trap with a 3/4" socket weld connection, stainless steel internals, and a max working pressure of 650 PSI. This steam trap has a strainer. The WT3000 is a medium capacity thermostatic steam trap which was specifically designed for removing condensate and air from process applications. The body is made from stainless steel and is fully repairable while the product remains in-line.
Requires Quote
Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel TA125-12-N is a stainless steel thermostatic steam trap with a 1/2" NPT connection, stainless steel internals, and a max working pressure of 125 PSI. The TA125 Series radiator traps with right angle connection are thermostatic steam traps that were specifically designed for removing condensate and air from 2-pipe steam heating systems. They can be fully repaired in-line by removing the cap and replacing the seat and thermal element.

$109.38$125.00

You save 12%
Low Stock (1)Ships within 1 business day
The Watson McDaniel TA125-13-N is a stainless steel thermostatic steam trap with a 3/4" NPT connection, stainless steel internals, and a max working pressure of 125 PSI. The TA125 Series radiator traps with right angle connection are thermostatic steam traps that were specifically designed for removing condensate and air from 2-pipe steam heating systems. They can be fully repaired in-line by removing the cap and replacing the seat and thermal element.

$183.29

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel TA25B-12-N is a stainless steel thermostatic steam trap with a 1/2" NPT connection, stainless steel internals, and a max working pressure of 25 PSI. The TA25B Series radiator traps with right angle connection are thermostatic steam traps that were specifically designed for removing condensate and air from 2-pipe steam heating systems. They can be fully repaired in-line by removing the cap and replacing the seat and thermal element.

$105.02

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel TA25B-13-N is a stainless steel thermostatic steam trap with a 3/4" NPT connection, stainless steel internals, and a max working pressure of 25 PSI. The TA25B Series radiator traps with right angle connection are thermostatic steam traps that were specifically designed for removing condensate and air from 2-pipe steam heating systems. They can be fully repaired in-line by removing the cap and replacing the seat and thermal element.

$165.45

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel TD3600-12-BW is a steel thermodynamic steam trap with a 1/2" butt weld connection, stainless steel internals, and a max operating pressure of 3600 PSI. TD3600 Series steam traps are designed to handle the drainage of condensate from extremely high pressure systems, and are commonly used as drip traps on high-pressure steam mains and steam supply lines. These traps are suitable for outdoor applications that are subject to freezing as well as superheated steam conditions. The complete intenal working mechanism can be completely replaced while the trap body remains in line.

$5,328.04

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel TD3600-12-F1500 is a steel thermodynamic steam trap with a 1/2" ANSI 1500# Flange connection, stainless steel internals, and a max operating pressure of 3600 PSI. TD3600 Series steam traps are designed to handle the drainage of condensate from extremely high pressure systems, and are commonly used as drip traps on high-pressure steam mains and steam supply lines. These traps are suitable for outdoor applications that are subject to freezing as well as superheated steam conditions. The complete intenal working mechanism can be completely replaced while the trap body remains in line.
Requires Quote
Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel TD3600-12-F600 is a steel thermodynamic steam trap with a 1/2" ANSI 600# Flange connection, stainless steel internals, and a max operating pressure of 3600 PSI. TD3600 Series steam traps are designed to handle the drainage of condensate from extremely high pressure systems, and are commonly used as drip traps on high-pressure steam mains and steam supply lines. These traps are suitable for outdoor applications that are subject to freezing as well as superheated steam conditions. The complete intenal working mechanism can be completely replaced while the trap body remains in line.
Requires Quote
Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel TD3600-12-SW is a steel thermodynamic steam trap with a 1/2" socket weld connection, stainless steel internals, and a max operating pressure of 3600 PSI. TD3600 Series steam traps are designed to handle the drainage of condensate from extremely high pressure systems, and are commonly used as drip traps on high-pressure steam mains and steam supply lines. These traps are suitable for outdoor applications that are subject to freezing as well as superheated steam conditions. The complete intenal working mechanism can be completely replaced while the trap body remains in line.

$4,844.58

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel TD3600-13-BW is a steel thermodynamic steam trap with a 3/4" butt weld connection, stainless steel internals, and a max operating pressure of 3600 PSI. TD3600 Series steam traps are designed to handle the drainage of condensate from extremely high pressure systems, and are commonly used as drip traps on high-pressure steam mains and steam supply lines. These traps are suitable for outdoor applications that are subject to freezing as well as superheated steam conditions. The complete intenal working mechanism can be completely replaced while the trap body remains in line.

$6,217.70

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel TD3600-13-F1500 is a steel thermodynamic steam trap with a 3/4" ANSI 1500# Flange connection, stainless steel internals, and a max operating pressure of 3600 PSI. TD3600 Series steam traps are designed to handle the drainage of condensate from extremely high pressure systems, and are commonly used as drip traps on high-pressure steam mains and steam supply lines. These traps are suitable for outdoor applications that are subject to freezing as well as superheated steam conditions. The complete intenal working mechanism can be completely replaced while the trap body remains in line.
Requires Quote
Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel SIBH-13-N-200 is a stainless steel inverted bucket steam trap with a 3/4" NPT connection, stainless steel internals, and a max working pressure of 200 PSI. The IB inverted bucket steam traps were specifically designed for removing condensate from steam mains & steam supply lines. Inverted bucket traps can also be used on unit heaters, laundry equipment, and other less critical process applications where slow start-up due to poor air handling characteristics can be tolerated. These traps can handle superheated steam when a check valve is used on the inlet side, which prevents the trap from losing prime.

$493.38

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel SIBH-13-N-250 is a stainless steel inverted bucket steam trap with a 3/4" NPT connection, stainless steel internals, and a max working pressure of 250 PSI. The IB inverted bucket steam traps were specifically designed for removing condensate from steam mains & steam supply lines. Inverted bucket traps can also be used on unit heaters, laundry equipment, and other less critical process applications where slow start-up due to poor air handling characteristics can be tolerated. These traps can handle superheated steam when a check valve is used on the inlet side, which prevents the trap from losing prime.

$493.38

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel SIBH-13-N-30 is a stainless steel inverted bucket steam trap with a 3/4" NPT connection, stainless steel internals, and a max working pressure of 30 PSI. The IB inverted bucket steam traps were specifically designed for removing condensate from steam mains & steam supply lines. Inverted bucket traps can also be used on unit heaters, laundry equipment, and other less critical process applications where slow start-up due to poor air handling characteristics can be tolerated. These traps can handle superheated steam when a check valve is used on the inlet side, which prevents the trap from losing prime.

$493.38

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel SIBH-13-N-450 is a stainless steel inverted bucket steam trap with a 3/4" NPT connection, stainless steel internals, and a max working pressure of 450 PSI. The IB inverted bucket steam traps were specifically designed for removing condensate from steam mains & steam supply lines. Inverted bucket traps can also be used on unit heaters, laundry equipment, and other less critical process applications where slow start-up due to poor air handling characteristics can be tolerated. These traps can handle superheated steam when a check valve is used on the inlet side, which prevents the trap from losing prime.

$493.38

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel SIBH-13-N-70 is a stainless steel inverted bucket steam trap with a 3/4" NPT connection, stainless steel internals, and a max working pressure of 70 PSI. The IB inverted bucket steam traps were specifically designed for removing condensate from steam mains & steam supply lines. Inverted bucket traps can also be used on unit heaters, laundry equipment, and other less critical process applications where slow start-up due to poor air handling characteristics can be tolerated. These traps can handle superheated steam when a check valve is used on the inlet side, which prevents the trap from losing prime.

$493.38

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel SIBH-13-SW-125 is a stainless steel inverted bucket steam trap with a 3/4" socket weld connection, stainless steel internals, and a max working pressure of 125 PSI. The IB inverted bucket steam traps were specifically designed for removing condensate from steam mains & steam supply lines. Inverted bucket traps can also be used on unit heaters, laundry equipment, and other less critical process applications where slow start-up due to poor air handling characteristics can be tolerated. These traps can handle superheated steam when a check valve is used on the inlet side, which prevents the trap from losing prime.

$493.38

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel SIBH-13-SW-15 is a stainless steel inverted bucket steam trap with a 3/4" socket weld connection, stainless steel internals, and a max working pressure of 15 PSI. The IB inverted bucket steam traps were specifically designed for removing condensate from steam mains & steam supply lines. Inverted bucket traps can also be used on unit heaters, laundry equipment, and other less critical process applications where slow start-up due to poor air handling characteristics can be tolerated. These traps can handle superheated steam when a check valve is used on the inlet side, which prevents the trap from losing prime.

$493.38

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel SIBH-13-SW-200 is a stainless steel inverted bucket steam trap with a 3/4" socket weld connection, stainless steel internals, and a max working pressure of 200 PSI. The IB inverted bucket steam traps were specifically designed for removing condensate from steam mains & steam supply lines. Inverted bucket traps can also be used on unit heaters, laundry equipment, and other less critical process applications where slow start-up due to poor air handling characteristics can be tolerated. These traps can handle superheated steam when a check valve is used on the inlet side, which prevents the trap from losing prime.

$493.38

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel SIBH-13-SW-250 is a stainless steel inverted bucket steam trap with a 3/4" socket weld connection, stainless steel internals, and a max working pressure of 250 PSI. The IB inverted bucket steam traps were specifically designed for removing condensate from steam mains & steam supply lines. Inverted bucket traps can also be used on unit heaters, laundry equipment, and other less critical process applications where slow start-up due to poor air handling characteristics can be tolerated. These traps can handle superheated steam when a check valve is used on the inlet side, which prevents the trap from losing prime.

$493.38

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel SIBH-13-SW-30 is a stainless steel inverted bucket steam trap with a 3/4" socket weld connection, stainless steel internals, and a max working pressure of 30 PSI. The IB inverted bucket steam traps were specifically designed for removing condensate from steam mains & steam supply lines. Inverted bucket traps can also be used on unit heaters, laundry equipment, and other less critical process applications where slow start-up due to poor air handling characteristics can be tolerated. These traps can handle superheated steam when a check valve is used on the inlet side, which prevents the trap from losing prime.

$493.38

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel SIBH-13-SW-450 is a stainless steel inverted bucket steam trap with a 3/4" socket weld connection, stainless steel internals, and a max working pressure of 450 PSI. The IB inverted bucket steam traps were specifically designed for removing condensate from steam mains & steam supply lines. Inverted bucket traps can also be used on unit heaters, laundry equipment, and other less critical process applications where slow start-up due to poor air handling characteristics can be tolerated. These traps can handle superheated steam when a check valve is used on the inlet side, which prevents the trap from losing prime.

$493.38

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel SIBH-13-SW-70 is a stainless steel inverted bucket steam trap with a 3/4" socket weld connection, stainless steel internals, and a max working pressure of 70 PSI. The IB inverted bucket steam traps were specifically designed for removing condensate from steam mains & steam supply lines. Inverted bucket traps can also be used on unit heaters, laundry equipment, and other less critical process applications where slow start-up due to poor air handling characteristics can be tolerated. These traps can handle superheated steam when a check valve is used on the inlet side, which prevents the trap from losing prime.

$493.38

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel ST3001S-12-SW is a stainless steel thermostatic steam trap with a 1/2" socket weld connection, stainless steel internals, and a max working pressure of 650 PSI. This steam trap has a strainer. The WT3000 is a medium capacity thermostatic steam trap which was specifically designed for removing condensate and air from process applications. The body is made from stainless steel and is fully repairable while the product remains in-line.
Requires Quote
Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel ST3001S-13-SW is a stainless steel thermostatic steam trap with a 3/4" socket weld connection, stainless steel internals, and a max working pressure of 650 PSI. This steam trap has a strainer. The WT3000 is a medium capacity thermostatic steam trap which was specifically designed for removing condensate and air from process applications. The body is made from stainless steel and is fully repairable while the product remains in-line.
Requires Quote
Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel TA125-12-N is a stainless steel thermostatic steam trap with a 1/2" NPT connection, stainless steel internals, and a max working pressure of 125 PSI. The TA125 Series radiator traps with right angle connection are thermostatic steam traps that were specifically designed for removing condensate and air from 2-pipe steam heating systems. They can be fully repaired in-line by removing the cap and replacing the seat and thermal element.

$109.38$125.00

You save 12%
Low Stock (1)Ships within 1 business day
The Watson McDaniel TA125-13-N is a stainless steel thermostatic steam trap with a 3/4" NPT connection, stainless steel internals, and a max working pressure of 125 PSI. The TA125 Series radiator traps with right angle connection are thermostatic steam traps that were specifically designed for removing condensate and air from 2-pipe steam heating systems. They can be fully repaired in-line by removing the cap and replacing the seat and thermal element.

$183.29

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel TA25B-12-N is a stainless steel thermostatic steam trap with a 1/2" NPT connection, stainless steel internals, and a max working pressure of 25 PSI. The TA25B Series radiator traps with right angle connection are thermostatic steam traps that were specifically designed for removing condensate and air from 2-pipe steam heating systems. They can be fully repaired in-line by removing the cap and replacing the seat and thermal element.

$105.02

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel TA25B-13-N is a stainless steel thermostatic steam trap with a 3/4" NPT connection, stainless steel internals, and a max working pressure of 25 PSI. The TA25B Series radiator traps with right angle connection are thermostatic steam traps that were specifically designed for removing condensate and air from 2-pipe steam heating systems. They can be fully repaired in-line by removing the cap and replacing the seat and thermal element.

$165.45

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel TD3600-12-BW is a steel thermodynamic steam trap with a 1/2" butt weld connection, stainless steel internals, and a max operating pressure of 3600 PSI. TD3600 Series steam traps are designed to handle the drainage of condensate from extremely high pressure systems, and are commonly used as drip traps on high-pressure steam mains and steam supply lines. These traps are suitable for outdoor applications that are subject to freezing as well as superheated steam conditions. The complete intenal working mechanism can be completely replaced while the trap body remains in line.

$5,328.04

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel TD3600-12-F1500 is a steel thermodynamic steam trap with a 1/2" ANSI 1500# Flange connection, stainless steel internals, and a max operating pressure of 3600 PSI. TD3600 Series steam traps are designed to handle the drainage of condensate from extremely high pressure systems, and are commonly used as drip traps on high-pressure steam mains and steam supply lines. These traps are suitable for outdoor applications that are subject to freezing as well as superheated steam conditions. The complete intenal working mechanism can be completely replaced while the trap body remains in line.
Requires Quote
Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel TD3600-12-F600 is a steel thermodynamic steam trap with a 1/2" ANSI 600# Flange connection, stainless steel internals, and a max operating pressure of 3600 PSI. TD3600 Series steam traps are designed to handle the drainage of condensate from extremely high pressure systems, and are commonly used as drip traps on high-pressure steam mains and steam supply lines. These traps are suitable for outdoor applications that are subject to freezing as well as superheated steam conditions. The complete intenal working mechanism can be completely replaced while the trap body remains in line.
Requires Quote
Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel TD3600-12-SW is a steel thermodynamic steam trap with a 1/2" socket weld connection, stainless steel internals, and a max operating pressure of 3600 PSI. TD3600 Series steam traps are designed to handle the drainage of condensate from extremely high pressure systems, and are commonly used as drip traps on high-pressure steam mains and steam supply lines. These traps are suitable for outdoor applications that are subject to freezing as well as superheated steam conditions. The complete intenal working mechanism can be completely replaced while the trap body remains in line.

$4,844.58

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel TD3600-13-BW is a steel thermodynamic steam trap with a 3/4" butt weld connection, stainless steel internals, and a max operating pressure of 3600 PSI. TD3600 Series steam traps are designed to handle the drainage of condensate from extremely high pressure systems, and are commonly used as drip traps on high-pressure steam mains and steam supply lines. These traps are suitable for outdoor applications that are subject to freezing as well as superheated steam conditions. The complete intenal working mechanism can be completely replaced while the trap body remains in line.

$6,217.70

Should ship between 16 Nov and 30 Nov

Subject to factory lead times

The Watson McDaniel TD3600-13-F1500 is a steel thermodynamic steam trap with a 3/4" ANSI 1500# Flange connection, stainless steel internals, and a max operating pressure of 3600 PSI. TD3600 Series steam traps are designed to handle the drainage of condensate from extremely high pressure systems, and are commonly used as drip traps on high-pressure steam mains and steam supply lines. These traps are suitable for outdoor applications that are subject to freezing as well as superheated steam conditions. The complete intenal working mechanism can be completely replaced while the trap body remains in line.
Requires Quote
Should ship between 16 Nov and 30 Nov

Subject to factory lead times