Flow control products measure, monitor and regulate the movement of liquids and gases through a process. Accurate flow data helps you control dosing, track usage, protect pumps from running dry and confirm that coo...
Flow meters measure the rate and total volume of liquids and gases moving through pipes and channels. Accurate flow data supports billing, batching, process control and efficiency improvements.
Flow Meter Types
- Magnetic flow meters – conductive liquids with no moving parts
- Turbine flow meters – clean, low-viscosity liquids
- Positive displacement meters – viscous fluids
- Thermal mass meters – gas flow
- Rotameters – simple visual indication
- Open channel and anemometer meters – water channels and airflow
Choosing a Flow Meter
The fluid, flow range, accuracy, pipe size and installation constraints decide the technology. Consider pressure drop, straight-run needs and output signals.
Centro can help you select flow meters for your fluid and application.
Shop by type: Anemometer Flow Meters | Magnetic Flow Meters | Turbine Flow Meters | Roto Meters | Thermal Flow Meters | Visual Flow Meters
Related categories: Flow Control | Flow Transmitters | Flow Sensors | Flow Switches | Flow Control Accessories
Visual flow meters give an at-a-glance reading of flow without power. Sight flow indicators and rotameters confirm flow in cooling, purge, dosing and lubrication lines.
Visual Meter Types
- Sight flow indicators – flappers, rotors and drip tubes
- Rotameters – variable area flow indication
- Paddle wheel indicators – rotating flow display
- Glass and plastic bodies – suit pressure and media
Choosing a Meter
Select by flow range, pressure, temperature and fluid compatibility. Visual meters are simple confirmation devices, so add transmitters when you need remote signals.
Centro supplies visual flow meters and sight indicators.
Related categories: Flow Meters | Gas Flow Meters | Thermal Flow Meters | Water Meters | Roto Meters
Flow switches monitor liquid or air flow and trigger alarms or shutdowns when flow is too low or too high. They protect pumps, heat exchangers, chillers and cooling systems.
Flow Switch Types
- Paddle flow switches – simple, rugged
- Thermal flow switches – no moving parts
- Piston and magnetic flow switches – precise set points
- Air flow switches – ducts and HVAC
Choosing a Switch
Select by media, flow range, pipe size, pressure and temperature. Adjustable set points add flexibility.
Centro supplies flow switches.
Related categories: Flow Control | Flow Transmitters | Flow Meters | Flow Sensors | Flow Control Accessories
Sight flow indicators are essential instruments used to visually monitor the flow of liquids and gases in a pipeline or process system. These transparent or glass-tube indicators allow operators to observe the presence, color, clarity, and flow rate of fluids, ensuring smooth operations and providing valuable insights into the process. Sight flow indicators are commonly used in industries like chemical processing, petrochemicals, pharmaceuticals, and water treatment, where real-time flow observation is critical for safety, quality control, and troubleshooting. With a wide range of designs and materials available, sight flow indicators offer reliable and easy-to-use solutions for monitoring fluid flow and ensuring the efficiency of industrial processes.
Related categories: Flow Meters | Accessories and Parts | Ultrasonic Flow Meters | Water Meters | Gas Flow Meters
Flow sensors detect and measure the movement of liquids and gases in a pipe or duct. They protect pumps from running dry, confirm cooling flow to machines and give your control system the feedback it needs.
Flow Sensor Technologies
- Thermal flow sensors – no moving parts, suitable for water, oil and air
- Paddle and vane sensors – simple, rugged flow detection
- Magnetic inductive sensors – for conductive liquids
- Ultrasonic clamp-on sensors – non-invasive measurement on existing pipe
- Vortex sensors – steam, gas and liquid applications
Choosing a Sensor
Consider the media, flow range, pipe size, temperature and pressure, and whether you need a switching point, a continuous analog signal or both. IO-Link sensors provide extra diagnostics. Follow the straight-run requirements for accurate readings.
Centro offers flow sensors for machine cooling, process monitoring and pump protection.
Related categories: Flow Control | Flow Meters | Flow Control Accessories | Flow Transmitters | Flow, pH & Conductivity Meters, Transmitters & Controllers
Water meters measure water use for billing, sub-metering, process control and conservation. Accurate metering helps you find leaks and control costs.
Water Meter Types
- Positive displacement meters – accurate at low flows
- Multi-jet meters – commercial service
- Turbine meters – higher flows
- Electromagnetic meters – no moving parts
- Pulse output meters – remote monitoring
Choosing a Meter
Select by flow range, pipe size, accuracy and output. Lead-free meters are required for potable water.
Centro supplies water meters for commercial and industrial use.
Related categories: Flow Meters | Ultrasonic Flow Meters | Gas Flow Meters | Sight Flow Indicators | Visual Flow Meters
Flow transmitters convert flow measurements into standard signals for control systems, so you can monitor, control and record flow remotely.
Transmitter Options
- 4-20 mA and HART outputs – standard integration
- Pulse outputs – totalizing and batching
- Digital communication – Modbus and Ethernet
- Remote and integral mounting – suit installation
Choosing a Transmitter
Match the transmitter to the sensor or meter type and output required. Consider display, power and hazardous area ratings.
Centro supplies flow transmitters for process monitoring.
Related categories: Flow Control | Flow Switches | Flow Meters | Flow Sensors | Flow Control Accessories
Flow meter accessories and parts keep flow meters accurate and in service. Replacement sensors, fittings, displays and kits extend meter life.
Parts Available
- Replacement sensors and rotors – restore accuracy
- Fittings and adapters – installation
- Remote displays – read meters from a distance
- Cables and connectors – signal wiring
- Calibration services – verify accuracy
Ordering Parts
Have your meter model and serial number ready. Some parts require factory calibration.
Centro supplies flow meter accessories and parts.
Related categories: Flow Meters | Sight Flow Indicators | Ultrasonic Flow Meters | Water Meters | Gas Flow Meters
Turbine flow meters measure liquid flow by counting the rotation of a turbine rotor. They're accurate and responsive in clean, low-viscosity liquids such as water, fuels and light chemicals.
Turbine Meter Features
- High accuracy – suitable for batching and blending
- Wide turndown – broad flow range
- Pulse and analog outputs – connect to totalizers and controls
- Sanitary and stainless versions – food and chemical service
Installation Tips
Provide enough straight pipe upstream and downstream, and install a strainer to protect the rotor. Viscosity changes affect accuracy, so turbines suit consistent, clean fluids.
Centro supplies turbine flow meters for water, fuel and chemical measurement.
Related categories: Flow Meters | Roto Meters | Magnetic Flow Meters | Thermal Flow Meters
Anemometer flow meters measure air and gas velocity, and from that, airflow volume, in ducts, vents and open spaces. HVAC technicians, industrial hygienists and plant engineers use them for balancing, ventilation checks and dust collection troubleshooting.
Anemometer Types
- Vane anemometers – rotating vanes for duct and grille readings
- Hot-wire (thermal) anemometers – sensitive low-velocity measurement
- Pitot tube meters – high-velocity and dirty air streams
- Inline airflow transmitters – continuous duct monitoring
- Multi-function meters – velocity, temperature and humidity in one tool
Choosing a Meter
Match the meter to your velocity range and where you'll measure, whether that's ducts, open faces, stacks or rooms. Hot-wire probes fit small holes but aren't suited to dirty or hot gas, while pitot tubes handle tougher conditions. Data logging and CFM calculations speed up reporting.
Centro carries anemometers and airflow meters for HVAC, ventilation and industrial air systems.
Related categories: Flow Meters | Magnetic Flow Meters | Turbine Flow Meters
$222.84
Subject to factory lead times
$27.94
Subject to factory lead times
$114.73
Subject to factory lead times
$115.18
Subject to factory lead times
$44.45
Subject to factory lead times
$133.79
Subject to factory lead times
$122.34
Subject to factory lead times
$113.97
Subject to factory lead times
$252.90
Subject to factory lead times
$93.83
Subject to factory lead times
$76.23
Subject to factory lead times
$473.80
Subject to factory lead times
$865.15
Subject to factory lead times
$255.22
Subject to factory lead times
$111.13
Subject to factory lead times
$2,204.28
Subject to factory lead times
$147.61
Subject to factory lead times
$284.42
Subject to factory lead times
$46.77
Subject to factory lead times
$24.81
Subject to factory lead times
$198.35
Subject to factory lead times
$105.21
Subject to factory lead times
$209.55
Subject to factory lead times
$277.46
Subject to factory lead times
$222.84
Subject to factory lead times
$27.94
Subject to factory lead times
$114.73
Subject to factory lead times
$115.18
Subject to factory lead times
$44.45
Subject to factory lead times
$133.79
Subject to factory lead times
$122.34
Subject to factory lead times
$113.97
Subject to factory lead times
$252.90
Subject to factory lead times
$93.83
Subject to factory lead times
$76.23
Subject to factory lead times
$473.80
Subject to factory lead times
$865.15
Subject to factory lead times
$255.22
Subject to factory lead times
$111.13
Subject to factory lead times
$2,204.28
Subject to factory lead times
$147.61
Subject to factory lead times
$284.42
Subject to factory lead times
$46.77
Subject to factory lead times
$24.81
Subject to factory lead times
$198.35
Subject to factory lead times
$105.21
Subject to factory lead times
$209.55
Subject to factory lead times
$277.46
Subject to factory lead times
- Measuring flow rate in a pipe requires a flow meter matched to the fluid type, pipe size, flow range, and accuracy requirement. For conductive liquids (water, chemicals, slurries), magnetic flow meters are the most popular choice — they have no moving parts, create no pressure drop, and handle dirty or abrasive fluids. For non-conductive liquids or retrofit installations where you can't cut the pipe, clamp-on ultrasonic flow meters mount externally and measure through the pipe wall. For applications requiring the highest accuracy or mass flow measurement (batching, custody transfer), Coriolis meters measure mass flow directly. For steam and gas, vortex meters are robust and widely used. For simple, low-cost local visual indication of flow rate, variable-area meters (rotameters) provide a direct reading without power or electronics. Flow switches are used when you only need to confirm flow is present or absent — for example, verifying cooling water is running before allowing a machine to start. The flow meter output (typically 4–20 mA) feeds back to a PLC or controller for monitoring, totalization, or closed-loop flow control.
- The flow meter technology must match the fluid type, pipe size, accuracy requirement, and process conditions. Magnetic (mag) flow meters measure conductive liquids (water, chemicals, slurries) using Faraday's law — they have no moving parts, handle dirty or abrasive fluids well, and are the default for water and wastewater applications. Ultrasonic flow meters (transit-time and Doppler) are non-intrusive and can be clamp-on, ideal for retrofit or applications where the pipe cannot be cut. Coriolis meters measure mass flow directly with very high accuracy — the premium choice for custody transfer, batching, and applications requiring density measurement. Vortex meters are robust and versatile for steam, gas, and liquid measurement in moderate-to-large pipe sizes. Variable-area meters (rotameters) provide simple, low-cost local visual indication of flow rate. Turbine meters offer high accuracy for clean, low-viscosity liquids. The best approach is to define the fluid properties, flow range, accuracy requirement, and installation constraints, then match to the technology that fits.
- A flow switch detects whether flow is present or absent (or above/below a threshold) and outputs a discrete on/off signal — it does not measure the actual flow rate. Flow switches are used for protection and alarm functions: confirming cooling water is flowing before allowing a machine to operate, detecting loss of lubrication flow to trigger a shutdown, or verifying that a pump is actually moving fluid. They are simpler and less expensive than flow meters. A flow meter, by contrast, measures the actual flow rate (GPM, liters/minute, SCFM, etc.) and provides a continuous analog or digital output proportional to the flow value. Flow meters are used when the control system needs to know how much fluid is flowing — for batching, dosing, energy accounting, and closed-loop flow control. If you only need to know whether flow is on or off, a flow switch is sufficient. If you need to know how much, you need a flow meter.
- A magnetic flow meter (mag meter) uses Faraday's law of electromagnetic induction to measure the velocity of a conductive liquid flowing through a pipe. The meter generates a magnetic field across the pipe, and the flowing conductive liquid produces a voltage proportional to its velocity — this voltage is measured by electrodes in the pipe wall and converted to a flow rate. Mag meters have several significant advantages: no moving parts (zero maintenance on the sensor itself), no obstruction to flow (full bore, no pressure drop), excellent performance with dirty, abrasive, and slurry-containing liquids, wide turndown ratios (typically 100:1 or greater), and bidirectional measurement capability. They are the standard choice for water and wastewater treatment, chemical processing, food and beverage, pharmaceutical, and pulp and paper applications. The main limitation is that the liquid must be electrically conductive (minimum ~5 µS/cm) — mag meters cannot measure hydrocarbons, deionized water, or gases.
- Flow meter sizing must balance accuracy, rangeability, and pressure drop. The meter should be sized so that the normal operating flow rate falls within the meter's optimal accuracy range — typically between 25% and 75% of its full-scale capacity. Sizing based solely on the pipe diameter is a common mistake — if the pipe is oversized for the actual flow rate (which is common in many installations), the flow velocity through the meter will be too low for accurate measurement. In these cases, the meter should be sized smaller than the pipe, with reducers and expanders installed to transition from the pipe size to the meter size. Key data needed for sizing includes the fluid type and properties (density, viscosity, conductivity, temperature, pressure), the minimum, normal, and maximum flow rates, the required accuracy, and the acceptable pressure drop. Most flow meter manufacturers provide online sizing tools where you input these parameters and receive a recommended meter size and model.