Instrumentation, Measurement and Control - E+E Elektronik
Instrumentation refers to devices that measure or control physical variables such as temperature, level, flow, or pressure. These products are essential in the industry because they allow for maximum output with mi...
Humidity sensors measure relative humidity and often temperature too, in buildings, cleanrooms, warehouses and processes. Controlling humidity protects products, prevents condensation and mold, and keeps people comfortable.
Humidity Sensor Types
- Duct-mount transmitters – HVAC air handlers and supply ducts
- Wall and room sensors – occupied spaces and storage
- Outdoor sensors – weather-protected housings
- Industrial probes – high temperature and process applications
- Dew point capable models – calculated dew point outputs
Choosing a Sensor
Select accuracy and range for your application, typically ±2-3% RH for HVAC and tighter for labs and cleanrooms. Choose outputs (4-20 mA, 0-10 V, BACnet, Modbus) to match your controls. Replaceable sensing elements make calibration and maintenance easier.
Centro supplies humidity sensors and transmitters for building automation and industrial monitoring.
Related categories: Sensors | Gas Detection Sensors | Moisture in Oil Sensors | Dew Point Sensors
Dew point sensors measure moisture in compressed air and gases. They confirm dryer performance and protect instrument air, pneumatics and moisture-sensitive processes.
Features
- Low dew point measurement – down to -60°C and below
- Fast response – catch dryer issues quickly
- Analog and digital outputs – monitoring and alarms
- Inline and sampling installation – flexible mounting
Choosing a Sensor
Select range for your dryer type and accuracy needs. Regular calibration keeps readings dependable. Dew point control on desiccant dryers saves purge air.
Centro supplies dew point sensors for compressed air monitoring.
Related categories: Sensors | Moisture in Oil Sensors | Gas Detection Sensors | Humidity Sensors
Anemometer flow meters measure air and gas velocity, and from that, airflow volume, in ducts, vents and open spaces. HVAC technicians, industrial hygienists and plant engineers use them for balancing, ventilation checks and dust collection troubleshooting.
Anemometer Types
- Vane anemometers – rotating vanes for duct and grille readings
- Hot-wire (thermal) anemometers – sensitive low-velocity measurement
- Pitot tube meters – high-velocity and dirty air streams
- Inline airflow transmitters – continuous duct monitoring
- Multi-function meters – velocity, temperature and humidity in one tool
Choosing a Meter
Match the meter to your velocity range and where you'll measure, whether that's ducts, open faces, stacks or rooms. Hot-wire probes fit small holes but aren't suited to dirty or hot gas, while pitot tubes handle tougher conditions. Data logging and CFM calculations speed up reporting.
Centro carries anemometers and airflow meters for HVAC, ventilation and industrial air systems.
Related categories: Flow Meters | Magnetic Flow Meters | Turbine Flow Meters
Gas detection sensors warn people when toxic or combustible gases reach dangerous levels. They protect workers in plants, confined spaces, treatment facilities and storage areas.
Gas Detection Types
- Combustible gas detectors – methane, propane and hydrogen
- Toxic gas detectors – H2S, CO, ammonia and chlorine
- Oxygen monitors – oxygen deficiency and enrichment
- Fixed and portable detectors – area and personal monitoring
- Controllers and alarms – alarms and ventilation control
Planning a System
Identify the gases present, their density and where they could collect. Sensor placement matters: lighter gases rise and heavier gases settle. Regular bump testing and calibration are essential.
Centro supplies gas detection sensors and controllers for workplace safety.
Related categories: Sensors | Humidity Sensors | Moisture in Oil Sensors | Dew Point Sensors
Moisture in oil sensors continuously measure water content in lubricating, hydraulic and transformer oils. Water speeds up wear, corrosion and oil breakdown, so early detection protects expensive equipment.
Features
- Water activity and ppm measurement – track moisture trends
- Inline installation – real-time monitoring
- Temperature output – combined oil condition data
- Analog and digital outputs – integrate with monitoring systems
Applications
Common uses include gearboxes, hydraulic systems, turbines, paper machines and transformers. Pair sensors with desiccant breathers and filtration to keep moisture under control.
Centro supplies moisture in oil sensors for condition monitoring.
Related categories: Sensors | Dew Point Sensors | Gas Detection Sensors | Humidity Sensors
$2,313.76$2,683.00
Subject to factory lead times
$1,878.39$2,178.00
Subject to factory lead times
$4,253.68$4,932.00
Subject to factory lead times
$3,607.55$4,181.00
Subject to factory lead times
$5,002.88$5,803.00
Subject to factory lead times
$1,169.19$1,355.00
Subject to factory lead times
$3,701.40$4,293.00
Subject to factory lead times
$2,313.76$2,683.00
Subject to factory lead times
$1,878.39$2,178.00
Subject to factory lead times
$4,253.68$4,932.00
Subject to factory lead times
$3,607.55$4,181.00
Subject to factory lead times
$5,002.88$5,803.00
Subject to factory lead times
$1,169.19$1,355.00
Subject to factory lead times
$3,701.40$4,293.00
Subject to factory lead times
- Selecting the right process instrument starts with defining four things: what variable you need to measure (temperature, pressure, flow, or level), the process conditions the instrument will face (media type, temperature range, pressure range, corrosiveness, and whether the environment is hazardous), the accuracy and response time your application requires, and how the measurement data needs to be communicated (local display only, 4–20 mA signal to a PLC/DCS, or digital protocol like HART or Modbus). For temperature, the choice between thermocouples, RTDs, and infrared sensors depends on the temperature range and accuracy needed. For pressure, gauge type, range, wetted materials, and whether you need local indication or a remote transmitter signal are the key decisions. For flow, the fluid properties (conductive liquid, gas, steam, slurry) determine whether a magnetic, ultrasonic, Coriolis, vortex, or variable-area meter is the best fit. For level, vessel conditions (open vs. pressurized, clean liquid vs. foam/solids) guide the choice between float switches, ultrasonic, radar, or differential pressure technologies. Centro's instrumentation specialists can help you match the right technology to your specific process conditions and budget.
- Accurate process instrumentation is the foundation of safe, efficient, and compliant operations. Every control loop — whether it manages boiler pressure, reactor temperature, tank level, or pipeline flow — depends on instruments that provide reliable, real-time measurements. If a temperature sensor reads inaccurately, a heater may overshoot and damage the product or create a safety hazard. If a level transmitter drifts, a tank may overflow or run dry. If a flow meter is undersized, the control system cannot maintain the correct feed rate. Beyond safety and quality, accurate instrumentation directly impacts energy consumption, raw material usage, and regulatory compliance. Calibrated, properly specified instruments reduce waste, prevent unplanned shutdowns, and provide the data required for regulatory reporting and quality documentation.
- A process control loop is a system that continuously measures a process variable, compares it to a desired setpoint, and adjusts an output to keep the variable at the setpoint. The loop consists of three elements: the sensor/transmitter (measures the variable — e.g., a thermocouple measuring temperature), the controller (compares the measurement to the setpoint and calculates a corrective output — typically a PID controller), and the final control element (adjusts the process — e.g., a control valve that opens or closes to change steam flow). Instruments are the eyes and ears of the loop — without accurate, responsive sensors and transmitters, the controller cannot make correct decisions, and the process drifts out of specification. The entire loop must be properly engineered as a system — sensor accuracy, transmitter range, controller tuning, and valve sizing must all be matched to the process requirements.
- Industrial instruments communicate with controllers and PLCs using standardized electrical signals. The 4–20 mA analog current loop is the most widely used signal in process instrumentation — it transmits a variable measurement as a proportional current (4 mA = zero/low range, 20 mA = full scale), and the current-based signal is resistant to voltage drop and electrical noise over long cable runs. The 0–10 V DC voltage signal is used in some HVAC and building automation applications but is more susceptible to noise and cable length limitations. Discrete (on/off) signals — from switches, relays, and transmitter alarm contacts — indicate threshold conditions like high level, low pressure, or flow/no-flow. Digital communication protocols — HART (layered on top of 4–20 mA for configuration and diagnostics), Foundation Fieldbus, PROFIBUS PA, and IO-Link — enable bidirectional communication between the instrument and the control system for advanced diagnostics, remote configuration, and multi-variable data.
- When instruments are installed in locations classified as hazardous (areas where flammable gases, vapors, or combustible dusts may be present), they must be approved for that classification to prevent ignition. Key considerations include the area classification (Class I for gases/vapors, Class II for dusts, with Division 1 for normally present hazards and Division 2 for abnormal conditions — or Zone 0/1/2 under ATEX/IECEx), the protection method (intrinsic safety, explosion-proof, non-incendive, or purged/pressurized), and the specific gas group and temperature class. Intrinsically safe (IS) instruments — used with IS barriers in the safe area — limit energy to levels too low to cause ignition and are the most common and practical approach for low-power sensors and transmitters. Explosion-proof enclosures contain any internal explosion and are used for higher-power devices. Always verify the instrument's certification (FM, CSA, ATEX, IECEx) matches the area classification before installation.